Steel is so much easier to work with and weighs practically nothing and is straight.
Ceiling joist attic loading.
If you have an attic over your garage these joists also bear the load of your attic flooring and any materials you store in the attic.
The wooden joists or beams over your garage help hold your roof in place.
Ceiling joist are 2x4.
If you need a storage area above your garage strong ceiling joists are necessary to support the added weight.
2 how much weight could the ceiling joist hold.
Attic ceiling joists with limited storage.
1 can the joist be cut to make room for the attic ladder.
The dead load on a floor is determined by the materials used in the floor s construction.
Screw the metal joist to the existing wood ceiling joist and to each plate and you have very effectively reduced the load deflection of any stored attic loads for little cost.
Span exceeds 26 feet in length.
Standard joist spacing for the installation of attic flooring materials is 16 inches on center oc meaning the distance from the center of one joist to the center of the next joist is 16 inches.
Girder load width half joist span live load on roof local requirements for wind and snow.
2attic loads may be included in the floor live load but a 10 psf attic load is typically used only to size ceiling joists adequately for access.
However in some cases the joists are intentionally built strong enough for the homeowner to later build out the attic.
Therefore if you have an attic space according to this scenario the ceiling joists can be designed for a live load of 10 pounds per square foot psf by using table r802 4 1.
Loads should be determined in accordance with this chapter.
If there s wall board covered ceiling suspended from the underside of that floor the dead load increases to about 10 pounds per square foot.
Hopefully the attached pictures provide additional info.
Unless expressly built so an attic s joists are meant for carrying the load of the ceiling below and related elements collectively known as the dead load.
When used for storage only dead load of attic floor not floored 10 lbs.
Single story house built in the 1940s.
The ceiling load may include items like drywall ducts recessed lights bathroom fans and attic insulation.
Ceiling joist are support by a wall that runs roughly down the middle of the house.
Most houses attics are built without flooring and are not designed to carry the heavy load of finished space.
Ft dead load of roof of wood shingle construction 10 lbs.
I have done this many times in rooms and older garages with sagging ceiling joists.
Ceiling joist spans for common lumber species uninhabitable attics with limited storage live load 20 psf l δ 240 check sources for availability of lumber in lengths greater than 20 feet.